Published July 19, 1985 | Version v1
Report Restricted

Simulation of glovebox nondestructive assay to aid in error estimation and measurement procedure design

Description

Gamma ray nondestructive assay (NDA) measurement procedures for large objects such as gloveboxes require that multiple measurements be made to cover the entire object. Net counts observed at each measurement location are converted to special nuclear material (SNM) equivalents using a data reduction equation. To facilitate rapid and reliable reduction of data, this equation is often a simple representation of the measurement situation. Using a single measurement procedure applied uniformly to many situations and a simple data reduction equation produce results that only approximate the quantity of SNM contained in the glovebox. This paper discusses a glovebox measurement simulation model and computer program that is being developed by Rockwell Hanford Operations. The model is being used to investigate some of the errors associated with current measurement and data reduction procedures. 6 figs

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE85017242.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
8 p.
Report number
RHO-SS-SA--18P

Conference

Title
26. annual meeting of the Institute of Nuclear Materials Management.
Dates
21-24 Jul 1985.
Place
Albuquerque, NM (USA).

Optional Information

Secondary number(s)
CONF-850765--33.