Published October 1981
| Version v1
Report
Restricted
TMX-Upgrade vacuum-system design and analysis
Description
This paper describes the design and analysis of the TMX Upgrade Vacuum System. TMX Upgrade is a modification of the TMX tandem mirror device. It will employ thermal barriers to further improve plasma confinement. Thermal barriers are produced by microwave heating and neutral-beam pumping. They increase the feasibility of tandem-mirror reactors by reducing both the required magnetic field strengths and the neutral-beam injection voltages
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.
Files
Additional details
Publishing Information
- Imprint Pagination
- 5 p.
- Report number
- UCRL--85981
Conference
- Title
- 9. symposium on engineering problems of fusion research.
- Dates
- 26 - 29 Oct 1981.
- Place
- Chicago, IL, USA.
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 13662870
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- GETTERING; HYDROGEN; SPECIFICATIONS; TITANIUM; TMX DEVICES; VACUUM SYSTEMS
- Descriptors DEC
- ELEMENTS; MAGNETIC MIRRORS; METALS; NONMETALS; OPEN PLASMA DEVICES; THERMONUCLEAR DEVICES; TRANSITION ELEMENTS
Optional Information
- Secondary number(s)
- CONF-811040--33.