Published January 1995 | Version v1
Journal article

Observation of Doppler shifted Tα emission from TFTR tritium neutral beams

  • 1. Princeton Plasma Physics Laboratory, P. O. Box 451, Princeton, New Jersey 08543 (United States)

Description

195 tritium ion source shots were injected into Tokamak Fusion Test Reactor (TFTR) high power plasmas during December 1993--March 1994. In addition, four highly diagnosed pulses were fired into the calorimeter. Analysis of the Doppler shifted Tα emission of the beam in the neutralizer has revealed that the extracted ion compositions for deuterium and tritium are indistinguishable: 0.72±0.04 D+; 0.22±0.02 D+2; 0.07±0.01 D+3 compared to 0.72±0.04 T+; 0.23±0.02 T+2; 0.05±0.01 T+3. The resultant tritium full-energy neutral fraction is higher than for deuterium due to the increased neutralization efficiency at lower velocity. To conserve tritium, it was used only for injection and a few calorimeter test shots, never for ion source conditioning. When used, the gas species were switched to tritium only for the shot in question. This resulted in an approximately 2% deuterium contamination of the tritium beam and vice versa for the first deuterium pulse following tritium. Data from the calorimeter shots indicate that tritium contamination of the deuterium beam cleans up in five to six beam pulses, and is reduced to immeasurable quantities prior to deuterium beam injection

Additional details

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
66
Journal Issue
1
Journal Page Range
p. 632-634.
ISSN
0034-6748
CODEN
RSINAK