Published 1976 | Version v1
Book

Failed fuel detection system

  • 1. Bhabha Atomic Research Centre, Bombay (India)
  • 2. Department of Atomic Energy, Bombay (India). Physics Committee

Description

The failed fuel detection system used at the Rajasthan Atomic Power Station consists of : (i) two count rate meter units, (ii) data acquisition unit, (iii) batch selector and driver unit, (iv) data display unit and (v) power supply unit. Each unit is described in detail. The performance of this system is satisfactory. Some improvements are suggested. (A.K.)

Additional details

Publishing Information

Publisher
Department of Atomic Energy.
Imprint Place
Bombay
Imprint Title
Symposium on nuclear reactor instrumentation [held at] Bombay [during] December 20-23, 1976 [papers]
Journal Page Range
p. 18-24.

Conference

Title
Symposium on nuclear reactor instrumentation.
Dates
20 - 23 Dec 1976.