Published February 1979 | Version v1
Report Restricted

Critical heat flux experiments with a local hot patch in an internally heated annulus (LWBR development program)

Description

Critical heat flux experiments were conducted for upflow of water in a vertical 84 inch annular flow channel, 0.303 inch heated I.D. and 0.500 inch unheated O.D. Test data were obtained at pressures from 1200 to 2000 psia, mass velocities from 0.25 x 106 to 2.8 x 106 lb/hr-ft2 and inlet temperatures ranging from 200 to 6000F. Three different test sections were employed with (1) axially uniform heat flux over the 84 inch length to serve as a no-hot-patch data base, (2) axially uniform heat flux over 82 inches with a 1.5 heat flux ratio hot patch over the last two inches, and (3) axially uniform heat flux over 82 inches with a 2.25 heat flux ratio hot patch over the last two inches

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
47 p.
Report number
WAPD-TM--1419