Safety analysis report: packages. LP-50 tritium package (packaging of fissile and other radioactive materials). Final report

Description

Elemental tritium is shipped at low pressure in a stainless steel container (LP-50) sealed within an aluminum vessel and surrounded by a minimum of 4-in. thick Celotex insulation in a steel drum. The structural, thermal, containment, shielding, and criticality safety aspects of this package are evaluated. Procedures for loading and unloading, empty cask transport, acceptance testing and maintenance, and quality assurance requirements for the LP-50 package are described in detail. (U.S.)

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
85 p.
Report number
DPSPU--74-124-5