Calculation note: project W-320 primary ventilation air flow requirements for mitigation of steady state flammable gas concentrations in the headspaces of tanks 241-C-106 and 241-AY-102
Description
This calculation note analyzes headspace concentrations of hydrogen dependent upon assumed ventilation flow rates provided for tanks 241-C-106 and 241-AY-102. The analyses are based on measured or estimated steady state hydrogen release rates. Tank 241-C-106 is analyzed prior to sluicing; tank 241-AY-102 is analyzed both prior to and after completion of sluicing. Specific analyses, using both best estimated and bounding hydrogen generation rates, include the minimum primary ventilation flow rates required in the tanks to ensure that the steady state hydrogen concentration in the respective tank headspace does not exceed 25% and 100% of the LFL. The headspace hydrogen concentration as a function of time as well as the time required to reach 25% and 100% of LFL upon complete loss of active ventilation, starting from the steady state hydrogen concentration based on a 200 CFM minimum flow rate in tank 241-C-106 and a 100 CFM minimum flow rate in tank241-AY-102. The headspace hydrogen concentration as a function of thee following partial loss of active ventilation (i.e., step changes to l60, l20, 80, and 40 CFM ventilation flow rates) in tank 241-C-106, staffing from a 200 CFM flow rate and the corresponding steady state hydrogen concentration based on the 200 CFM flow rate. The headspace hydrogen concentration as a function of the following partial loss of active ventilation i.e., step changes to 80, 60, 40, and 20 CFM ventilation flow rates) in tank 241-AY-102, starting from a 100 CFM flow rate and the corresponding steady state hydrogen concentration based on the 100 CFM flow rate
Availability note (English)
Available from INIS in electronic form; ALSO AVAILABLE FROM OSTI AS DE99050010; NTIS; US GOVT. PRINTING OFFICE DEP.Files
30035840.pdf
Files
(318.5 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:6bc4aa5c33bdf3674b8bd56c696ac448
|
318.5 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 22 p.
- Report number
- HNF-SD-WM-CN--114
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 30035840
- Subject category
- S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES; S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Descriptors DEI
- CHEMICAL ANALYSIS; GASES; HYDROGEN; RADIOACTIVE WASTE STORAGE; TANKS; TIME DEPENDENCE
- Descriptors DEC
- CONTAINERS; ELEMENTS; FLUIDS; MANAGEMENT; NONMETALS; STORAGE; WASTE MANAGEMENT; WASTE STORAGE
Optional Information
- Contract/Grant/Project number
- Contract AC06-96RL13200
- Funding organization
- USDOE Office of Environmental Restoration and Waste Management, Washington, DC (United States)