Published 2010 | Version v1
Journal article

Measurement of the indoor and outdoor 220Rn (thoron) equilibrium factor: Application to lung dose

  • 1. New York Univ. School of Medicine, Dept. of Environmental Medicine, 550 First Avenue, New York NY 10016 (United States)
  • 2. ORNL UT-Battelle, PO Box 2008 Bldg 2007, MS 6042, Oak Ridge TN 37831 (United States)
  • 3. Dade Moeller and Associates, 1835 Terminal Drive, Suite 200, Richland WA 99354 (United States)

Description

A miniature four-chamber alpha track detector was developed that measures both 222Rn (radon) and 220Rn (thoron), in duplicate. Using this detector and the previous long-term measurements of the 220Rn decay products 212Pb, and 212Bi, an equilibrium factor, Feq, is derived for both outdoor and indoor 220Rn environments (0.004+0.001 outdoors and 0.04+0.01 indoors). The lung airway dose can then be calculated from a dose factor from UNSCEAR that requires the equilibrium equivalent thoron concentration (EEC), i.e. the product of Feq and the 220Rn gas concentration. The lung dose from thoron in domestic or occupational surveys is often overlooked. The values of Feq for thoron in several published studies are in general agreement with the values reported here. Thus, a long-term alpha track measurement of thoron multiplied by an appropriate indoor or outdoor equilibrium factor yields the EEC, which can be used to assess bronchial lung dose. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncq228

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
141
Journal Issue
4
Journal Page Range
p. 357-362
ISSN
0144-8420

Conference

Title
International workshop on environmental thoron and related issues
Dates
19-22 May 2010
Place
Chiba (Japan)

Optional Information

Notes
13 refs