Published November 9, 1994
| Version v1
Report
Open
PFP up-right lift UL-20/26 manlifts
Description
This Technical Evaluation of Equipment Maintenance (TEEM) is provided principally to document vendor suggested maintenance requirements and deviations from vendor suggested requirements, and provide documentation to support PM procedures. As additional maintenance activities are identified, they will be documented in later revisions. This TEEM is applicable to four single-person manlifts. The report documents preventive maintenance evaluations, semi-annual checks, safety rules before the use of the manlifts, and routine service checks
Availability note (English)
MF available from INIS under the Report Number; Also available from OSTI as DE95003839; NTIS; US Govt. Printing Office Dep.Files
26037452.pdf
Files
(557.2 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:969a8770e140de14157daae324befb1d
|
557.2 kB | Preview Download |
Additional details
Additional titles
- Augmented title (English)
- Plutonium Finishing Plant
Publishing Information
- Imprint Pagination
- 18 p.
- Report number
- WHC-SD--CP-TEEM-069
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 26037452
- Subject category
- S42: ENGINEERING; S11: NUCLEAR FUEL CYCLE AND FUEL MATERIALS;
- Descriptors DEI
- CRANES; FUEL REPROCESSING PLANTS; HANFORD RESERVATION; MAINTENANCE; PERSONNEL; RECOMMENDATIONS; REMOTE HANDLING
- Descriptors DEC
- EQUIPMENT; MATERIALS HANDLING EQUIPMENT; NATIONAL ORGANIZATIONS; NUCLEAR FACILITIES; REMOTE HANDLING EQUIPMENT; US DOE; US ORGANIZATIONS
Optional Information
- Contract/Grant/Project number
- Contract AC06-87RL10930
- Funding organization
- USDOE, Washington, DC (United States).