Published January 1983 | Version v1
Journal article

Leak detection by vibrational diagnostic methods

Creators

  • 1. Villamosenergiaipari Kutato Intezet, Budapest (Hungary)

Description

The possibilities and methods of leak detection due to mechanical failures in nuclear power plants are reviewed on the basis of the literature. Great importance is attributed to vibrational diagnostic methods for their adventageous characteristics which enable them to become final leak detecting methods. The problems of noise analysis, e.g. leak detection by impact sound measurements, probe characteristics, gain problems, probe selection, off-line analysis and correlation functions, types of leak noises etc. are summarized. Leak detection based on noise analysis can be installed additionally to power plants. Its maintenance and testing is simple. On the other hand, it requires special training and measuring methods. (Sz.J.)

Additional details

Additional titles

Original title (Hungarian)
Szivargasdetektalas rezgesdiagnosztikai modszerekkel
Augmented title (English)
using noise analysis, in reactor cooling systems

Publishing Information

Journal Title
Energ. Atomtech.
Journal Volume
36
Journal Issue
1
Series
Energ. Atomtech.
Journal Page Range
38-48
ISSN
0013-7316

Optional Information

Notes
13 refs.