Published March 1998 | Version v1
Journal article

Reconstruction of the system of high pressure heaters in 'Oslomej' power plant - Kichevo (Macedonia)

  • 1. Faculty of Mechanical Engineering, St. 'Cyril and Methodius' University, Skopje (The Frmr.Yug.Rep. of Macedonia)

Description

Immediately after the commissioning of the Power Plant 'Oslomej' - Kicevo, it was detected malfunctioning of the automatic regulation system of the high pressure heaters (HPH). By the means of manual level maintain, full or partial by-passing of HPH by applying water, as well as rejecting the condensed flow to the effluent collecting tank or condenser, the working personal tried to ensure necessary working conditions, followed by energy losses, surplus of fuel consumption, additional air pollution, high thermal elongation, increased thrust in the axial bear and a lot of problems with steam inlet parameters. In this paper the preposition and execution of a new solution is presented. Through authors' self solution as well as use of contemporary equipment for power, control and regulation (HONEYWELL, KSB), a reconstruction of the system (HPH) has been successfully done. (author)

Additional details

Additional titles

Original title (Macedonian)
Rekonstrukcija na sistemot za visokopritisna regeneracija vo REK 'Oslomej' - Kichevo. IIdel: Predlog i izvedba na novoto reshenie

Publishing Information

Journal Title
Energetika
Journal Volume
6
Journal Issue
16
Journal Page Range
p. 28-30
ISSN
1409-6048

Optional Information

Notes
Part II: Preposition and execution of a new solution; 1 fig.; UDC: 621.182.1:681.5; 621.311.22.004.67(497.17)