The SF6 recovery and storage system of a dynamitron accelerator

  • 1. Stuttgart Univ. (TH) (F.R. Germany). Inst. fuer Strahlenphysik

Description

An SF6 recovery and storage system has been designed and built for a dynamitron accelerator with a 40 m3 tank with an operating pressure of about 7 bar. The system works semi-automatically and is protected by safety devices and controls. The time required for evacuating the SF6 from the accelerator tank down to a pressure of 0.1 mbar is only 2.5 hours. In another operating mode of the system the SF6 can be recirculated through a desiccating filter and a dust filter during operation of the accelerator, bringing the dew point of the gas down to -600C. (orig.)

Abstract (German)

Es wurde ein SF6-Umfuellsystem fuer einen Dynamitron-Beschleuniger mit einem 40-m3-Tank und einem Betriebsdruck von 7 bar entwickelt und gebaut. Das System arbeitet halbautomatisch und wird durch eine Sicherheitsinstrumentierung ueberwacht. Die Zeit zum Abpumpen des SF6 aus dem Beschleunigertank bis zu einem Druck von 0,1 mbar betraegt nur 2,5 Stunden. In einer anderen Betriebsart kann das SF6 durch ein Staub- und Trockenfilter umgepumpt werden, waehrend der Beschleuniger in Betrieb ist; der Taupunkt des Gases erniedrigt sich dabei auf -600C. (orig.)

Additional details

Publishing Information

Journal Title
Kerntechnik
Journal Volume
17
Journal Issue
11
Series
Kerntechnik.
Journal Page Range
471-476

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
7242522
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
ACCELERATOR FACILITIES; CONTROL EQUIPMENT; DYNAMITRONS; FILTERS; LABORATORY EQUIPMENT; SULFUR FLUORIDES
Descriptors DEC
ACCELERATORS; ELECTROSTATIC ACCELERATORS; FLUORIDES; FLUORINE COMPOUNDS; HALIDES; HALOGEN COMPOUNDS; SULFUR COMPOUNDS

Optional Information

Notes
3 figs.; 2 refs.