Published November 1975
| Version v1
Journal article
The SF6 recovery and storage system of a dynamitron accelerator
- 1. Stuttgart Univ. (TH) (F.R. Germany). Inst. fuer Strahlenphysik
Description
An SF6 recovery and storage system has been designed and built for a dynamitron accelerator with a 40 m3 tank with an operating pressure of about 7 bar. The system works semi-automatically and is protected by safety devices and controls. The time required for evacuating the SF6 from the accelerator tank down to a pressure of 0.1 mbar is only 2.5 hours. In another operating mode of the system the SF6 can be recirculated through a desiccating filter and a dust filter during operation of the accelerator, bringing the dew point of the gas down to -600C. (orig.)
Abstract (German)
Es wurde ein SF6-Umfuellsystem fuer einen Dynamitron-Beschleuniger mit einem 40-m3-Tank und einem Betriebsdruck von 7 bar entwickelt und gebaut. Das System arbeitet halbautomatisch und wird durch eine Sicherheitsinstrumentierung ueberwacht. Die Zeit zum Abpumpen des SF6 aus dem Beschleunigertank bis zu einem Druck von 0,1 mbar betraegt nur 2,5 Stunden. In einer anderen Betriebsart kann das SF6 durch ein Staub- und Trockenfilter umgepumpt werden, waehrend der Beschleuniger in Betrieb ist; der Taupunkt des Gases erniedrigt sich dabei auf -600C. (orig.)Additional details
Publishing Information
- Journal Title
- Kerntechnik
- Journal Volume
- 17
- Journal Issue
- 11
- Series
- Kerntechnik.
- Journal Page Range
- 471-476
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 7242522
- Subject category
- S43: PARTICLE ACCELERATORS;
- Descriptors DEI
- ACCELERATOR FACILITIES; CONTROL EQUIPMENT; DYNAMITRONS; FILTERS; LABORATORY EQUIPMENT; SULFUR FLUORIDES
- Descriptors DEC
- ACCELERATORS; ELECTROSTATIC ACCELERATORS; FLUORIDES; FLUORINE COMPOUNDS; HALIDES; HALOGEN COMPOUNDS; SULFUR COMPOUNDS
Optional Information
- Notes
- 3 figs.; 2 refs.