Correlative feature analysis on FFDM

  • 1. Department of Radiology, Committee on Medical Physics, University of Chicago, 5841 South Maryland Avenue, MC 2026 Chicago, Illinois 60637 (United States)

Description

Identifying the corresponding images of a lesion in different views is an essential step in improving the diagnostic ability of both radiologists and computer-aided diagnosis (CAD) systems. Because of the nonrigidity of the breasts and the 2D projective property of mammograms, this task is not trivial. In this pilot study, we present a computerized framework that differentiates between corresponding images of the same lesion in different views and noncorresponding images, i.e., images of different lesions. A dual-stage segmentation method, which employs an initial radial gradient index (RGI) based segmentation and an active contour model, is applied to extract mass lesions from the surrounding parenchyma. Then various lesion features are automatically extracted from each of the two views of each lesion to quantify the characteristics of density, size, texture and the neighborhood of the lesion, as well as its distance to the nipple. A two-step scheme is employed to estimate the probability that the two lesion images from different mammographic views are of the same physical lesion. In the first step, a correspondence metric for each pairwise feature is estimated by a Bayesian artificial neural network (BANN). Then, these pairwise correspondence metrics are combined using another BANN to yield an overall probability of correspondence. Receiver operating characteristic (ROC) analysis was used to evaluate the performance of the individual features and the selected feature subset in the task of distinguishing corresponding pairs from noncorresponding pairs. Using a FFDM database with 123 corresponding image pairs and 82 noncorresponding pairs, the distance feature yielded an area under the ROC curve (AUC) of 0.81±0.02 with leave-one-out (by physical lesion) evaluation, and the feature metric subset, which included distance, gradient texture, and ROI-based correlation, yielded an AUC of 0.87±0.02. The improvement by using multiple feature metrics was statistically significant compared to single feature performance.

Additional details

Identifiers

Publishing Information

Journal Title
Medical Physics
Journal Volume
35
Journal Issue
12
Journal Page Range
p. 5490-5500
ISSN
0094-2405
CODEN
MPHYA6

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
44053421
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE; S97: MATHEMATICAL METHODS AND COMPUTING;
Descriptors DEI
ALGORITHMS; BIOMEDICAL RADIOGRAPHY; DIAGNOSIS; IMAGE PROCESSING; IMAGES; MAMMARY GLANDS; PERFORMANCE; PROBABILISTIC ESTIMATION
Descriptors DEC
BODY; CALCULATION METHODS; DIAGNOSTIC TECHNIQUES; GLANDS; MATHEMATICAL LOGIC; MEDICINE; NUCLEAR MEDICINE; ORGANS; PROCESSING; RADIOLOGY

Optional Information

Notes
(c) 2008 American Association of Physicists in Medicine