Published August 2007 | Version v1
Journal article

99mTc-labelled HYNIC-minigastrin with reduced kidney uptake for targeting of CCK-2 receptor-positive tumours

  • 1. Innsbruck Medical University, Clinical Department of Nuclear Medicine, Innsbruck (Austria)
  • 2. Innsbruck Medical University, Central Laboratory Animal Facilities, Innsbruck (Austria)
  • 3. Innsbruck Medical University, Clinical Department of Radiotherapy and Radiooncology, Innsbruck (Austria)

Description

Different attempts have been made to develop a suitable radioligand for targeting CCK-2 receptors in vivo, for staging of medullary thyroid carcinoma (MTC) and other receptor-expressing tumours. After initial successful clinical studies with [DTPA0,DGlu1]minigastrin (DTPA-MG0) radiolabelled with 111In and 90Y, our group developed a 99mTc-labelled radioligand, based on HYNIC-MG0. A major drawback observed with these derivatives is their high uptake by the kidneys. In this study we describe the preclinical evaluation of the optimised shortened peptide analogue, [HYNIC0,DGlu1,desGlu2-6]minigastrin (HYNIC-MG11). 99mTc labelling of HYNIC-MG11 was performed using tricine and EDDA as coligands. Stability experiments were carried out by reversed phase HPLC analysis in PBS, PBS/cysteine and plasma as well as rat liver and kidney homogenates. Receptor binding and cell uptake experiments were performed using AR4-2J rat pancreatic tumour cells. Animal biodistribution was studied in AR4-2J tumour-bearing nude mice. Radiolabelling was performed at high specific activities and radiochemical purity was >90%. 99mTc-EDDA-HYNIC-MG11 showed high affinity for the CCK-2 receptor and cell internalisation comparable to that of 99mTc-EDDA-HYNIC-MG0. Despite high stability in solution, a low metabolic stability in rat tissue homogenates was found. In a nude mouse tumour model, very low unspecific retention in most organs, rapid renal excretion with reduced renal retention and high tumour uptake were observed. 99mTc-EDDA-HYNIC-MG11 shows advantages over 99mTc-EDDA-HYNIC-MG0 in terms of lower kidney retention with unchanged uptake in tumours and CCK-2 receptor-positive tissue. However, the lower metabolic stability and impurities formed in the labelling process still leave room for further improvement. (orig.)

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00259-006-0348-3

Additional details

Identifiers

Publishing Information

Journal Title
European Journal of Nuclear Medicine and Molecular Imaging
Journal Volume
34
Journal Issue
8
Journal Page Range
p. 1209-1218
ISSN
1619-7070