Published September 2015 | Version v1
Journal article

For a better estimation of gamma heating in nuclear material-testing reactors and associated devices. Status and work plan from calculation methods to nuclear data

  • 1. French Alternative Energies and Atomic Energy Commission CEA, DEN, DER, Cadarache, Saint Paul Les Durance (France)
  • 2. Aix Marseille Universite, CNRS, Universite de Toulon, IM2NP UMR 7334, Marseille (France)

Description

The determination of gamma heating levels in material-testing reactors (MTRs) is of crucial importance as gamma heating affects both safety and performance parameters of MTRs. The required accuracy (5% at one standard deviation) makes it necessary to calibrate bias and uncertainty associated with MTR gamma-heating calculations. Main steps of bias determination for gamma-heating calculations include, first, the development of a calculation methodology with the controlled use of physical approximations; second, the interpretation of gamma-heating measurements with reference calculations so as to determine bias supposed to be mainly due to nuclear data. (author)

Availability note (English)

Available from http://dx.doi.org/10.1080/00223131.2015.1009957

Additional details

Publishing Information

Journal Title
Journal of Nuclear Science and Technology (Tokyo)
Journal Volume
52
Journal Issue
9
Journal Page Range
p. 1093-1101
ISSN
0022-3131

Optional Information

Notes
23 refs., 1 fig., 3 tabs.