TH-C-BRD-12: Robust Intensity Modulated Proton Therapy Plan Can Eliminate Junction Shifts for Craniospinal Irradiation
Creators
- 1. UT MD Anderson Cancer Center, University of Houston, Houston, TX (United States)
- 2. UT MD Anderson Cancer Center, Tianjin Medical University Cancer Instit, Houston, TX (United States)
- 3. Varian Medical Systems, Houston, TX (United States)
- 4. UT MD Anderson Cancer Center, Houston, Texas (United States)
- 5. UT MD Anderson Cancer Center, Houston, TX (United States)
- 6. University of Houston, Houston, Texas (United States)
Description
Purpose: The passive scattering proton therapy (PSPT) technique is the commonly used radiotherapy technique for craniospinal irradiation (CSI). However, PSPT involves many numbers of junction shifts applied over the course of treatment to reduce the cold and hot regions caused by field mismatching. In this work, we introduced a robust planning approach to develop an optimal and clinical efficient techniques for CSI using intensity modulated proton therapy (IMPT) so that junction shifts can essentially be eliminated. Methods: The intra-fractional uncertainty, in which two overlapping fields shift in the opposite directions along the craniospinal axis, are incorporated into the robust optimization algorithm. Treatment plans with junction sizes 3,5,10,15,20,25 cm were designed and compared with the plan designed using the non-robust optimization. Robustness of the plans were evaluated based on dose profiles along the craniospinal axis for the plans applying 3 mm intra-fractional shift. The dose intra-fraction variations (DIV) at the junction are used to evaluate the robustness of the plans. Results: The DIVs are 7.9%, 6.3%, 5.0%, 3.8%, 2.8% and 2.2%, for the robustly optimized plans with junction sizes 3,5,10,15,20,25 cm. The DIV are 10% for the non-robustly optimized plans with junction size 25 cm. The dose profiles along the craniospinal axis exhibit gradual and tapered dose distribution. Using DIVs less than 5% as maximum acceptable intrafractional variation, the overlapping region can be reduced to 10 cm, leading to potential reduced number of the fields. The DIVs are less than 5% for 5 mm intra-fractional shifts with junction size 25 cm, leading to potential no-junction-shift for CSI using IMPT. Conclusion: This work is the first report of the robust optimization on CSI based on IMPT. We demonstrate that robust optimization can lead to much efficient carniospinal irradiation by eliminating the junction shifts
Additional details
Identifiers
- DOI
- 10.1118/1.4889610;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 41
- Journal Issue
- 6
- Journal Page Range
- p. 553
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 46115712
- Subject category
- S60: APPLIED LIFE SCIENCES;
- Descriptors DEI
- ALGORITHMS; BRAIN; COMPARATIVE EVALUATIONS; PLANNING; PROTON BEAMS; RADIATION DOSE DISTRIBUTIONS; RADIOTHERAPY; SPINAL CORD
- Descriptors DEC
- BEAMS; BODY; CENTRAL NERVOUS SYSTEM; EVALUATION; MATHEMATICAL LOGIC; MEDICINE; NERVOUS SYSTEM; NUCLEAR MEDICINE; NUCLEON BEAMS; ORGANS; PARTICLE BEAMS; RADIOLOGY; THERAPY
Optional Information
- Notes
- (c) 2014 American Association of Physicists in Medicine