Published May 2014 | Version v1
Miscellaneous

Sensitivity of Sump Water Temperature to Containment Integrity

  • 1. Nuclear Engineering Service and Solution, Daejeon (Korea, Republic of)

Description

This paper is focused on the containment behavior analysis in the above described cases using GOTHIC-IST (generation of thermal-hydraulic information for containments, industry standard toolset). GOTHIC-IST version 7.2a is an integrated, general purpose thermal-hydraulics software package for design, licensing, safety and operating analysis of nuclear power plant containments and other confinement buildings. In this study, we perform the sensitivity the sump water temperature to containment integrity. For 35% RIH break accident with the malfunction of spray system, local air coolers, ECC(emergency core cooling) pump and heat exchanger, the peak pressure at boiler room do not exceed the design pressure 124kPa(g) of the containment and containment integrity is secured. If accompanied the malfunction of heat exchanger or pump in the time of low pressure safety injection, of ECCS, it will be one of the aggravating factors to the integrity of core and containment

Part of:
Proceedings of the KNS 2014 spring meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Daejeon (Korea, Republic of)
Imprint Title
Proceedings of the KNS 2014 spring meeting
Imprint Pagination
[1 CD-ROM]
Journal Page Range
[2 p.]

Conference

Title
2014 spring meeting of the KNS
Dates
28-30 May 2014
Place
Jeju (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
46050515
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
CONTAINMENT; COOLING SYSTEMS; DESIGN; HEAT EXCHANGERS; LOSS OF COOLANT; PUMPS; SENSITIVITY
Descriptors DEC
ACCIDENTS; ENERGY SYSTEMS; EQUIPMENT; REACTOR ACCIDENTS

Optional Information

Notes
5 refs, 2 figs