Sensitivity of Sump Water Temperature to Containment Integrity
Creators
- 1. Nuclear Engineering Service and Solution, Daejeon (Korea, Republic of)
Description
This paper is focused on the containment behavior analysis in the above described cases using GOTHIC-IST (generation of thermal-hydraulic information for containments, industry standard toolset). GOTHIC-IST version 7.2a is an integrated, general purpose thermal-hydraulics software package for design, licensing, safety and operating analysis of nuclear power plant containments and other confinement buildings. In this study, we perform the sensitivity the sump water temperature to containment integrity. For 35% RIH break accident with the malfunction of spray system, local air coolers, ECC(emergency core cooling) pump and heat exchanger, the peak pressure at boiler room do not exceed the design pressure 124kPa(g) of the containment and containment integrity is secured. If accompanied the malfunction of heat exchanger or pump in the time of low pressure safety injection, of ECCS, it will be one of the aggravating factors to the integrity of core and containment
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Daejeon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS 2014 spring meeting
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [2 p.]
Conference
- Title
- 2014 spring meeting of the KNS
- Dates
- 28-30 May 2014
- Place
- Jeju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 46050515
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- CONTAINMENT; COOLING SYSTEMS; DESIGN; HEAT EXCHANGERS; LOSS OF COOLANT; PUMPS; SENSITIVITY
- Descriptors DEC
- ACCIDENTS; ENERGY SYSTEMS; EQUIPMENT; REACTOR ACCIDENTS
Optional Information
- Notes
- 5 refs, 2 figs