Published November 2019 | Version v1
Journal article

Estimation of organ doses and effective doses based on in-phantom dosimetry for paediatric diagnostic cardiac catheterisation

  • 1. Department of Radiological Technology, Kanagawa Children's Medical Centre, Mutsukawa 2-138-4, Minami-ku, Yokohama (Japan)

Description

The present study evaluated the organ doses, effective doses and conversion factors from the dose-area product to effective dose in pediatric diagnostic cardiac catheterization performed by in-phantom dosimetry and Monte Carlo simulation. The organ and effective doses in 5-y-olds during diagnostic cardiac catheterizations were evaluated using radiophotoluminescence glass dosemeters implanted into a pediatric anthropomorphic phantom and PCXMC software. The mean effective dose was 3.8 mSv (range: 1.8-7.5 mSv). The conversion factors from the dose-area product to effective dose were 0.9 and 1.6 mSv (Gy cm2)-1 for posteroanterior and lateral fluoroscopy, respectively, and 0.9 and 1.5 mSv (Gy cm2)-1 for posteroanterior and lateral cine-angiography, respectively. Effective doses evaluated using the pediatric dosimetry system agreed with those obtained using PCXMC software within 12%. The dose data and conversion factors evaluated may guide the estimation of exposure doses in children undergoing diagnostic cardiac catheterization. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncy298

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
185
Journal Issue
2
Journal Page Range
p. 215-221
ISSN
0144-8420

Optional Information

Notes
21 refs.