Published August 2016
| Version v1
Journal article
Correlation coefficient method to calculate the nuclear safety equipment qualification sample representativeness
- 1. Nuclear Safety and Radiation Center, MEP, Beijing (China)
Description
The representativeness of nuclear safety equipment qualification sample is directly related to that whether the qualification conclusion can be extrapolated to the actual equipment. The qualification sample representativeness criteria in IEEE standard and the sample selection method are discussed. A sample representativeness calculation method based on correlation coefficient is proposed. The sample representativeness obtained by the method can be quantified and the results are accurate. (authors)
Additional details
Publishing Information
- Journal Title
- Nuclear Electronics and Detection Technology
- Journal Volume
- 36
- Journal Issue
- 8
- Journal Page Range
- p. 842-846
- ISSN
- 0258-0934
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 53032574
- Subject category
- S99: GENERAL AND MISCELLANEOUS;
- Descriptors DEI
- CALCULATION METHODS; CORRELATIONS; EQUIPMENT; NUCLEAR POWER PLANTS; QUALITY ASSURANCE; RADIATION PROTECTION
- Descriptors DEC
- MANAGEMENT; NUCLEAR FACILITIES; POWER PLANTS; QUALITY MANAGEMENT; THERMAL POWER PLANTS
Optional Information
- Notes
- 2 figs., 6 tabs., 5 refs.