Correlation coefficient method to calculate the nuclear safety equipment qualification sample representativeness

  • 1. Nuclear Safety and Radiation Center, MEP, Beijing (China)

Description

The representativeness of nuclear safety equipment qualification sample is directly related to that whether the qualification conclusion can be extrapolated to the actual equipment. The qualification sample representativeness criteria in IEEE standard and the sample selection method are discussed. A sample representativeness calculation method based on correlation coefficient is proposed. The sample representativeness obtained by the method can be quantified and the results are accurate. (authors)

Additional details

Publishing Information

Journal Title
Nuclear Electronics and Detection Technology
Journal Volume
36
Journal Issue
8
Journal Page Range
p. 842-846
ISSN
0258-0934

INIS

Country of Publication
China
Country of Input or Organization
China
INIS RN
53032574
Subject category
S99: GENERAL AND MISCELLANEOUS;
Descriptors DEI
CALCULATION METHODS; CORRELATIONS; EQUIPMENT; NUCLEAR POWER PLANTS; QUALITY ASSURANCE; RADIATION PROTECTION
Descriptors DEC
MANAGEMENT; NUCLEAR FACILITIES; POWER PLANTS; QUALITY MANAGEMENT; THERMAL POWER PLANTS

Optional Information

Notes
2 figs., 6 tabs., 5 refs.