Published December 2017 | Version v1
Book

Development of a setup for measuring the afterglow scintillating materials

  • 1. Technical Physics Division, Bhabha Atomic Research Centre, Mumbai (India)

Description

The scintillating materials are essential for the technology developments as they find various applications including high energy physics, security, medical and industries. The main ideal scintillator characteristics include high light yield, fast decay time, high density, high radiation and mechanical hardness and low afterglow. The afterglow is basically defined with the emitted light left after switching off the higher energy radiation. High afterglow not only decreases the light the application output of the scintillator, it has also deterministic effect like the ghost effect in radiography and limits the application of scintillating materials in various devices. The afterglow mainly depends on the scintillation kinetics and defect structure of the materials

Part of:
Proceedings of the DAE-BRNS symposium on nuclear physics. V. 62

Additional details

Publishing Information

Publisher
Bhabha Atomic Research Centre
Imprint Place
Mumbai (India)
Imprint Title
Proceedings of the DAE-BRNS symposium on nuclear physics. V. 62
Imprint Pagination
[1220 p.]
Journal Page Range
p. 1126-1127

Conference

Title
62. DAE-BRNS symposium on nuclear physics
Dates
20-24 Dec 2017
Place
Patiala (India)

INIS

Country of Publication
India
Country of Input or Organization
India
INIS RN
49014856
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DEFECTS; FABRICATION; GLOW CURVE; RADIATION SOURCES; READOUT SYSTEMS; SCINTILLATION COUNTERS
Descriptors DEC
MEASURING INSTRUMENTS; RADIATION DETECTORS

Optional Information

Notes
2 refs., 2 figs.