Study of NaK flow and heat transfer, (1)

  • 1. Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center

Description

NaK might be used as a primary coolant of the core catcher system, if necessary, of LMFBR ''MONJU''. From this point of view NaK flow and heat transfer test loop has been designed and is now under construction. The purposes of the test loop are to acquire the handling technique of NaK alloy, to examine such equipments as the electromagnetic pump, the electromagnetic flow meter, the plugging indicator and the cold trap. In this report, the information was gathered on the foundamental characteristics and physical quantities of NaK alloy prior to the construction

Availability note (English)

MF available from INIS under the Report Number.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Additional titles

Subtitle (English)
Tabulation of the physical quantities of NaK

Publishing Information

Imprint Pagination
33 p.
Report number