Published 1996
| Version v1
Book
Evaluation of postulate events in laboratory irradiators
Creators
- 1. Centro de Proteccion e Higiene de las Radiaciones, La Habana (Cuba)
Description
In the present work are used the methods of logic-master graphs and failure trees for the evaluation of the irradiator OB6 of the Secondary Laboratory of Dosimetric Calibration of the Center for Hygiene and radiation Protection and the gamma cell 500 of the National Center of Agricultural Safety
Additional details
Additional titles
- Original title (Spanish)
- Evaluacion de sucesos postulados en irradiadores de laboratorio
Publishing Information
- Publisher
- Centro de Informacion de la Energia Nuclear
- Imprint Place
- La Habana (Cuba)
- Imprint Title
- 2nd Workshop on Nuclear Safety and Radiation Protection
- Imprint Pagination
- 255 p.
- Journal Page Range
- p. 190-192
INIS
- Country of Publication
- Cuba
- Country of Input or Organization
- Cuba
- INIS RN
- 29054039
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Descriptors DEI
- ACCIDENTS; EVALUATION; IRRADIATION DEVICES; NUCLEAR FACILITIES; RADIATION PROTECTION
Optional Information
- Notes
- Imprint:II Taller de Seguridad Nuclear y Radiologica