Published December 1986 | Version v1
Journal article

Specifications of a five-axes-goniometer for ion beam channeling technique

  • 1. Hiroshima Univ. (Japan). Faculty of Engineering

Description

For ion beam channeling experiments, we have equipped the Van de Graaff accelerator with a goniometer which has three rotational axes and two translational axes, and which can be remotely operated in a high vacuum. (author)

Additional details

Publishing Information

Journal Title
Hiroshima Daigaku Kogakubu Kenkyu Hokoku
Journal Volume
35
Journal Issue
1
Series
Hiroshima Daigaku Kogakubu Kenkyu Hokoku.
Journal Page Range
149-153
ISSN
0018-2060
CODEN
HIDKA

INIS

Country of Publication
Japan
Country of Input or Organization
Japan
INIS RN
18090535
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
CHANNELING; GONIOMETERS; ION BEAMS; SPECIFICATIONS; TARGET CHAMBERS; USES; VAN DE GRAAFF ACCELERATORS
Descriptors DEC
ACCELERATOR FACILITIES; ACCELERATORS; BEAMS; ELECTROSTATIC ACCELERATORS; MEASURING INSTRUMENTS