Published April 2006 | Version v1
Journal article

X-ray fluorescence analysis of soft materials using needle-type collimators enabling greater tolerance in analysis depth

  • 1. Department of Applied Chemistry, Graduate School of Engineering, Osaka City University, Sugimoto 3-3-138, Sumiyoshi-ku Osaka 558-8585 (Japan) and PRESTO-JST - Precursory Research for Embryonic Science and Technology, Japan Science and Technology Agency, 4-1-8 Honcho Kawaguchi, Saitama (Japan)
  • 2. Department of Applied Chemistry, Graduate School of Engineering, Osaka City University, Sugimoto 3-3-138, Sumiyoshi-ku Osaka 558-8585 (Japan)
  • 3. PRESTO-JST -Precursory Research for Embryonic Science and Technology, Japan Science and Technology Agency, 4-1-8 Honcho Kawaguchi, Saitama (Japan)

Description

A simple micro-X-ray fluorescence (XRF) method was proposed by using commercially available injection needles. Two needles were arranged in confocal configuration inside the sample. One injection needle, which was connected directly to an X-ray tube, was used as an X-ray guide to irradiate X-rays into the sample. Another needle, which was also inserted into the sample, was used to detect the X-ray fluorescence excited inside the sample. From the beam size, the analyzing volume was evaluated to be 0.24 mm3. Therefore, the X-ray fluorescence emitted from a micro region inside the sample could be detected, although this method can only be applied for soft samples. It was demonstrated that the X-ray fluorescence of Zn in a gelatin sample could be measured, and a good linear relationship was obtained for this element. X-ray fluorescence from an oyster sample was also successfully measured by using the injection needles collimator system

Additional details

Identifiers

DOI
10.1016/j.sab.2006.01.014;
PII
S0584-8547(06)00044-9;

Publishing Information

Journal Title
Spectrochimica Acta. Part B, Atomic Spectroscopy
Journal Volume
61
Journal Issue
4
Journal Page Range
p. 460-464
ISSN
0584-8547
CODEN
SAASBH

Conference

Title
34. colloquium spectroscopicum internationale
Dates
4-9 Sep 2005
Place
Antwerp (Belgium)

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
38082612
Subject category
S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BEAMS; COLLIMATORS; FLUORESCENCE; X RADIATION; X-RAY FLUORESCENCE ANALYSIS; X-RAY TUBES
Descriptors DEC
CHEMICAL ANALYSIS; ELECTROMAGNETIC RADIATION; ELECTRON TUBES; EMISSION; EQUIPMENT; IONIZING RADIATIONS; LUMINESCENCE; NONDESTRUCTIVE ANALYSIS; PHOTON EMISSION; RADIATIONS; X-RAY EMISSION ANALYSIS; X-RAY EQUIPMENT

Optional Information

Copyright
Copyright (c) 2006 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.