Published November 2001 | Version v1
Journal article

Simulation study of multi-step model algorithmic control of the nuclear reactor thermal power tracking system

  • 1. Harbin Inst. of Technology, Harbin (China). Simulation Center

Description

The classical control method is usually hard to ensure the thermal power tracking accuracy, because the nuclear reactor system is a complex nonlinear system with uncertain parameters and disturbances. A sort of non-parameter model is constructed with the open-loop impulse response of the system. Furthermore, a sort of thermal power tracking digital control law is presented using the multi-step model algorithmic control principle. The control method presented had good tracking performance and robustness. It can work despite the existence of unmeasurable disturbances. The simulation experiment testifies the correctness and effectiveness of the method. The high accuracy matching between the thermal power and the referenced load is achieved

Additional details

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
35
Journal Issue
6
Journal Page Range
p. 525-530
ISSN
1000-6931