Published November 1996
| Version v1
Report
Open
Thomson scattering in the EXTRAP-T2 reversed-field pinch
Description
A Thomson scattering system has been installed on the EXTRAP-T2 RFP experiment. The system measures the electron density and temperature in three radial points using three spectral channels. A description of the system, the calibration techniques and examples of data obtained are given. The error bars for the electron temperature measurements are estimated to be < 10% for typical T2-plasmas. 4 refs
Availability note (English)
MF available from INIS under the Report Number.Files
28032642.pdf
Files
(514.8 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:8d6eae8c8ec43807d686c22f392cc45e
|
514.8 kB | Preview Download |
Additional details
Publishing Information
- Imprint Pagination
- 32 p.
- Report number
- KTH-ALF-R--96-5
INIS
- Country of Publication
- Sweden
- Country of Input or Organization
- Sweden
- INIS RN
- 28032642
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- CALIBRATION; ELECTRON DENSITY; ELECTRON TEMPERATURE; PLASMA DIAGNOSTICS; REVERSED-FIELD PINCH DEVICES; THOMSON SCATTERING
- Descriptors DEC
- CLOSED PLASMA DEVICES; INELASTIC SCATTERING; PINCH DEVICES; SCATTERING; THERMONUCLEAR DEVICES; TOROIDAL PINCH DEVICES