Published November 2012 | Version v1
Journal article

Time-resolved CT angiography in aortic dissection

  • 1. Department of Clinical Radiology, Ludwig Maximilians-University, Marchioninistr. 15, 81377 Munich (Germany)
  • 2. Department of Surgery, Ludwig Maximilians-University, Marchioninistr. 15, 81377 Munich (Germany)

Description

Objectives: We performed this study to assess feasibility and additional diagnostic value of time-resolved CT angiography of the entire aorta in patients with aortic dissection. Materials and methods: 14 consecutive patients with known or suspected aortic dissection (aged 60 ± 9 years) referred for aortic CT angiography were scanned on a dual-source CT scanner (Somatom Definition Flash; Siemens, Forchheim, Germany) using a shuttle mode for multiphasic image acquisition (range 48 cm, time resolution 6 s, 6 phases, 100 kV, 110 mAs/rot). Effective radiation doses were calculated from recorded dose length products. For all phases, CT densities were measured in the aortic lumen and renal parenchyma. From the multiphasic data, 3 phases corresponding to a triphasic standard CT protocol, served as a reference and were compared against findings from the time-resolved datasets. Results: Mean effective radiation dose was 27.7 ± 3.5 mSv. CT density of the true lumen peaked at 355 ± 53 HU. Compared to the simulated triphasic protocol, time-resolved CT angiography added diagnostic information regarding a number of important findings: the enhancement delay between true and false lumen (n = 14); the degree of membrane oscillation (n = 14); the perfusion delay in arteries originating from the false lumen (n = 9). Other additional information included true lumen collapse (n = 4), quantitative assessment of renal perfusion asymmetry (n = 2), and dynamic occlusion of aortic branches (n = 2). In 3/14 patients (21%), these additional findings of the multiphasic protocol altered patient management. Conclusions: Multiphasic, time-resolved CT angiography covering the entire aorta is feasible at a reasonable effective radiation dose and adds significant diagnostic information with therapeutic consequences in patients with aortic dissection.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2012.03.006

Additional details

Identifiers

DOI
10.1016/j.ejrad.2012.03.006;
PII
S0720-048X(12)00101-5;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
81
Journal Issue
11
Journal Page Range
p. 3254-3261
ISSN
0720-048X
CODEN
EJRADR

Optional Information

Copyright
Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.