Time-resolved CT angiography in aortic dissection
Creators
- 1. Department of Clinical Radiology, Ludwig Maximilians-University, Marchioninistr. 15, 81377 Munich (Germany)
- 2. Department of Surgery, Ludwig Maximilians-University, Marchioninistr. 15, 81377 Munich (Germany)
Description
Objectives: We performed this study to assess feasibility and additional diagnostic value of time-resolved CT angiography of the entire aorta in patients with aortic dissection. Materials and methods: 14 consecutive patients with known or suspected aortic dissection (aged 60 ± 9 years) referred for aortic CT angiography were scanned on a dual-source CT scanner (Somatom Definition Flash; Siemens, Forchheim, Germany) using a shuttle mode for multiphasic image acquisition (range 48 cm, time resolution 6 s, 6 phases, 100 kV, 110 mAs/rot). Effective radiation doses were calculated from recorded dose length products. For all phases, CT densities were measured in the aortic lumen and renal parenchyma. From the multiphasic data, 3 phases corresponding to a triphasic standard CT protocol, served as a reference and were compared against findings from the time-resolved datasets. Results: Mean effective radiation dose was 27.7 ± 3.5 mSv. CT density of the true lumen peaked at 355 ± 53 HU. Compared to the simulated triphasic protocol, time-resolved CT angiography added diagnostic information regarding a number of important findings: the enhancement delay between true and false lumen (n = 14); the degree of membrane oscillation (n = 14); the perfusion delay in arteries originating from the false lumen (n = 9). Other additional information included true lumen collapse (n = 4), quantitative assessment of renal perfusion asymmetry (n = 2), and dynamic occlusion of aortic branches (n = 2). In 3/14 patients (21%), these additional findings of the multiphasic protocol altered patient management. Conclusions: Multiphasic, time-resolved CT angiography covering the entire aorta is feasible at a reasonable effective radiation dose and adds significant diagnostic information with therapeutic consequences in patients with aortic dissection.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2012.03.006Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2012.03.006;
- PII
- S0720-048X(12)00101-5;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 81
- Journal Issue
- 11
- Journal Page Range
- p. 3254-3261
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 45027659
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- AORTA; ASYMMETRY; BIOMEDICAL RADIOGRAPHY; CAT SCANNING; COMPARATIVE EVALUATIONS; COMPUTERIZED SIMULATION; DIAGNOSIS; FEDERAL REPUBLIC OF GERMANY; IMAGES; KIDNEYS; MEMBRANES; OSCILLATIONS; PATIENTS; RABBIT TUBES; RADIATION DOSES; TIME RESOLUTION
- Descriptors DEC
- ARTERIES; BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; COMPUTERIZED TOMOGRAPHY; DEVELOPED COUNTRIES; DIAGNOSTIC TECHNIQUES; DOSES; EUROPE; EVALUATION; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; REACTION PRODUCT TRANSPORT SYSTEMS; REACTOR COMPONENTS; REACTOR EXPERIMENTAL FACILITIES; RESOLUTION; SIMULATION; TIMING PROPERTIES; TOMOGRAPHY; WESTERN EUROPE
Optional Information
- Copyright
- Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.