Published June 1987 | Version v1
Journal article

Molybdenum and tungsten sublimation during atomic emission determinations

  • 1. Tadzhikskij Gosudarstvennyj Univ., Dushanbe (USSR)

Description

Conditions of atomic emission analysis of rocks, excluding systematic error of determining molybdenum and tungsten are studied. It is stated that use of potassium hydrosulfate or potassium carbonate and sulphur mixture as a reagent promotes production of molybdenum and tungsten high-volatile (under conditions of chamber electrode) compounds. For both sublimation variants the relative systematic error of atomic emission analysis doesn't exceed 10%; the detection limit constitutes (3-4)x10-5% for molybdenum and 1x10-4% for tungsten. The time of analysis for one sample is 45-50 min

Additional details

Additional titles

Original title (Russian)
Возгонка молибдена и вольфрама при выполнении атомно-эмиссионных определений

Publishing Information

Journal Title
Zh. Anal. Khim.
Journal Volume
42
Journal Issue
6
Series
Zh. Anal. Khim.
Journal Page Range
1068-1072
ISSN
0044-4502
CODEN
ZAKHA