Published 1975 | Version v1
Book

Dynamic analysis of steam isolation valve for closure under faulted conditions

  • 1. Teledyne Materials Research Co., Waltham, Mass. (USA)
  • 2. Southern Services, Inc., Birmingham, Alabama, USA
  • 3. Atwood and Morrill Company, Salem, Mass., USA

Description

The paper is concerned with an evaluation of the structural response of a swing-disk steam-isolation valve in the event of an emergency closure, such as postulated in conjunction with a pipe break in a main steam line of a nuclear power station. Described are the analytical approach, the results obtained from the dynamic analysis, and the acceptance criteria adopted for evaluating the results. (Auth.)

Additional details

Publishing Information

Publisher
North-Holland.
Imprint Place
Amsterdam, The Netherlands
Imprint Title
Structural mechanics in reactor technology
Imprint Pagination
v. 2 p. F6/10 1-14.

Conference

Title
3. international conference on structural mechanics in reactor technology.
Dates
1 Sep 1975.
Place
London, UK.