Reference Range of Functional Data of Gated Myocardial Perfusion SPECT by Quantitative Gated SPECT of Cedars-Sinai and 4D-MSPECT of Michigan University
Creators
- 1. College of Medicine, Univ. of Donga, Pusan (Korea, Republic of)
Description
Various programs have been developed for gating of myocardial perfusion SPECT. Among the those program, the most popular program is the Quantitative Gated SPECT (QGS)? developed by Cedars-Sinai hospital and most recently released program is 4D-MSPECT? developed by university of Michigan. It is important to know the reference range of the functional data of gated myocardial perfusion SPECT because it is necessary to determine abnormality of individual patient and echocardiographic data is different from those of gated SPECT. Tc-99m MIBI gated myocardial perfusion SPECT image was reconstructed by dual head gamma camera (Siemens, BCAM, esoft) as routine procedure and analyzed using QGS? and 4D-MSPECT? program. All patients (M: F=9: 18, Age 69±9 yrs) showed normal myocardial perfusion. The patients with following characteristics were excluded: previous angina or MI history, ECG change with Q wave or ST-T change, diabetes melitius, hypercholesterolemia, typical chest pain, hypertension and cardiomyopathy. Pre-test likelihood of all patients was low. (1) In stress gated SPECT by QGS?, EDV was 73±25 ml, ESV 25±14 ml, EF 67±11 % and area of first frame of gating 106.4±21cm2. In rest gated SPECT, EDV was 76±26 ml, ESV 27±15 ml, EF 66±12 and area of first frame of gating 108±20cm2. (2) In stress gated SPECT by 4D-MSPECT?, EDV was 76±28 ml, ESV 23±16 ml, EF 72±11 %, mass 115±24 g and ungated volume 42±15 ml. In rest gated SPECT, EDV was 75±27 ml, ESV 23±12 ml, EF 71±9%, mass 113±25g and ungate dvolume 42±15 ml, (3) s-EDV, s-EF, r-ESV and r-EF were significantly different between QGS? and 4D-MSPECT? (each p=0.016, p<0.001. p=0.003 and p=0.001). We determined the normal reference range of functional parameters by QGS? and 4D-MSPECT? program to diagnose individually the abnormality of patients. And the reference ranges have to adopted to be patients by each specific gating program
Additional details
Publishing Information
- Publisher
- KSNM
- Imprint Place
- Seoul (Korea, Republic of)
- Imprint Title
- Proceedings of the Korean Society Nuclear Medicine Autumn Meeting 2003
- Imprint Pagination
- [366 p.]
- Journal Page Range
- [9 p.]
Conference
- Title
- 42. Annual Autumn Meeting of the Korean Society Nuclear Medicine
- Dates
- 14-15 Nov 2003
- Place
- Seoul (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 37022477
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- DIAGNOSIS; GAMMA CAMERAS; MYOCARDIUM; PATIENTS; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; TECHNETIUM 99
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; BODY; CAMERAS; CARDIOVASCULAR SYSTEM; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; HEART; HOURS LIVING RADIOISOTOPES; INTERMEDIATE MASS NUCLEI; INTERNAL CONVERSION RADIOISOTOPES; ISOMERIC TRANSITION ISOTOPES; ISOTOPES; MUSCLES; NUCLEI; ODD-EVEN NUCLEI; ORGANS; RADIOISOTOPES; TECHNETIUM ISOTOPES; TOMOGRAPHY; YEARS LIVING RADIOISOTOPES