Published 1987 | Version v1
Book

Virginia Power thermal-hydraulics methods

  • 1. Virginia Power-IN35, Richmond, VA (USA)

Description

Virginia Power's nuclear safety analysis group is responsible for the safety analysis of reload cores for the Surry and North Anna power stations, including the area of core thermal-hydraulics. Postulated accidents are evaluated for potential departure from nucleate boiling violations. In support of these tasks, Virginia Power has employed the COBRA code and the W-3 and WRB-1 DNB correlations. A statistical DNBR methodology has also been developed. The code, correlations and statistical methodology are discussed

Additional details

Publishing Information

Publisher
American Nuclear Society.
Imprint Place
La Grange Park, IL (USA)
ISBN
0-89448-135-5
Imprint Title
Proceedings of the third nuclear thermal hydraulics meeting
Imprint Pagination
132 p.
Journal Page Range
p. 3-7.

Conference

Title
3. ANS winter meeting on nuclear thermal hydraulics.
Dates
15-19 Nov 1987.
Place
Los Angeles, CA (USA).

Optional Information

Secondary number(s)
CONF-8711210--.