Published November 1992
| Version v1
Report
Open
Recent performance, lifetime, and failure modes or the 5045 klystron population at SLAC
Creators
- 1. Stanford Linear Accelerator Center, Menlo Park, CA (United States)
Description
The 65 MW S-Band klystrons (5045) used to power SLC have been in service for over seven years. Currently, 244 of these tubes are in place on the accelerator, operating full power at 120 pulses per second. Enough tubes have now reached cathode end of life, or experienced other failures to allow a good analysis of failure modes, and to project average lifetime for this type of tube. This paper describes the various modes of failure seen in klystrons returned from SLC service, and provides data on expected lifetime from current production based on accumulated SLC operating experience. 3 refs., 6 figs
Files
28053605.pdf
Files
(100.5 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:f9edea39446794d7c5852368f4b74652
|
100.5 kB | Preview Download |
Additional details
Publishing Information
- Imprint Title
- Proceedings of the 1992 linear accelerator conference
- Imprint Pagination
- 949 p.
- Journal Page Range
- p. 740-742.
- Report number
- AECL--10728(Vol.1,2)
Conference
- Title
- 1992 Linear Accelerator Conference.
- Dates
- 24-28 Aug 1992.
- Place
- Ottawa, ON (Canada).
INIS
- Country of Publication
- Canada
- Country of Input or Organization
- Canada
- INIS RN
- 28053605
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- FAILURE MODE ANALYSIS; KLYSTRONS; PERFORMANCE; SERVICE LIFE; STANFORD LINEAR COLLIDER
- Descriptors DEC
- ACCELERATORS; ELECTRON TUBES; ELECTRONIC EQUIPMENT; EQUIPMENT; LIFETIME; LINEAR ACCELERATORS; LINEAR COLLIDERS; MICROWAVE EQUIPMENT; MICROWAVE TUBES; SYSTEM FAILURE ANALYSIS; SYSTEMS ANALYSIS
Optional Information
- Contract/Grant/Project number
- Contract DE-AC03-76SF00515