Published September 2005 | Version v1
Journal article

Assessment of two different software solutions for the evaluation of CT colonography

  • 1. Inst. fuer Diagnostische Radiologie, Universitaetsklinikum, Heinrich-Heine-Univ. Duesseldorf (Germany)
  • 2. Inst. fuer Informatik, Heinrich-Heine-Univ. Duesseldorf (Germany)
  • 3. Klinik fuer Gastroenterologie, Hepatologie und Infektiologie, Universitaetsklinikum, Heinrich-Heine-Univ. Duesseldorf (Germany)

Description

Purpose: To compare a commercial CT colonography software ('Colonography', Siemens, Forchheim) with a non-commercial post-processing system ('Colotux', Department of Informatics). Material and methods: Identical data sets of 10 patients, who underwent an ultra-low-dose multi-detector CT colonography (ULD-MDCTC) (4 x 1 mm collimation, 8 mm pitch, 120 kVp, 10 mAs) were analyzed retrospectively. Assessment was performed using both software solutions by two resident radiologists, who did not have any experience with any colonography software tool before and who did not know the clinical symptoms of the patients or the results of the conventional colonoscopy. Both systems were analyzed using several subjective quality criteria including workflow, handling, image quality, endoluminal navigation and analysis of lesions with grading on a 5-point-scale. Results concerning polyps were compared between the two systems as well as with conventional colonoscopy. Results: Both colonography systems detected the same number of polyps. Although both showed some advantages for single criteria, no relevant difference was noted in general for subjective assessment. The time for calculation of three dimensional interactive volumes was three times longer for 'Colotux' compared to 'Colonography'. Linux-based 'Colotux' showed a trend towards better subjective image quality and easier measurement of polyp size. An intuitive desktop and 'Syngo'-workflow integration were advantages of 'Colonography'. Conclusion: The analysis of CT colonographies (4-detector-row-CT-scanner, ultra low dose technique, supine position) can adequately be achieved by both software solutions. There was no significant subjective or objective difference of quality between a 'stand-alone' individual system and a commerical workflow-integrated solution. A relevant factor for decision between the two systems may be the difference in time needed for the 3D volume calculation, especially in institutes with a high frequency of examinations. (orig.)

Additional details

Additional titles

Original title (German)
Evaluation zwei verschiedener Softwareloesungen zur Auswertung von CT-Kolonographien

Publishing Information

Journal Title
RoeFo - Fortschritte auf dem Gebiete der Roentgenstrahlen und der bildgebenden Verfahren
Journal Volume
177
Journal Issue
9
Journal Page Range
p. 1227-1234
ISSN
1438-9029
CODEN
RFGNDO

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
36107747
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
COMPARATIVE EVALUATIONS; COMPUTERIZED TOMOGRAPHY; DATA ANALYSIS; DATA PROCESSING; INTESTINES
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; EVALUATION; GASTROINTESTINAL TRACT; ORGANS; PROCESSING; TOMOGRAPHY