Published 2018 | Version v1
Journal article

Visualization of radiation scattering in an X-ray room for teaching radiation protection

  • 1. Teikyo University, Faculty of Fukuoka Medical Technology, Omuta, Fukuoka (Japan)
  • 2. Kyushu University, Graduate School of Medical Sciences, Fukuoka, (Japan)

Description

It is important to reduce avoidable radiation exposure of health care workers and patients at radiography room in hospitals. For this purpose, teaching methods/tools that can explain basics of radiation protection is useful. Here, we propose a new teaching tool for radiation protection at a general radiography room. X-ray scattering at the general radiography room is mapped by using a Monte Carlo simulation code, PHITS. The radiography room is modeled with a simple geometric form. Therefore, the model can be changed easily to fit each radiography room even by a PHITS beginner. Visualization of X-ray scattering in each radiography room help the effective understanding of radiation protection. Our teaching tool is useful to reduce the unnecessary radiation exposure in radiography rooms. (author)

Availability note (English)

Available from DOI: https://doi.org/10.3769/radioisotopes.67.11

Abstract (Japanese)

一般の病院等ではX線撮影装置がその有用性から広く普及している一方,患者・介助者や医療従事者への不必要な被ばく量増大の可能性がある。本研究では放射線防護教育を目的としたX線撮影室内での放射線散乱の可視化図の作成を行った。モンテカルロシミュレーションコードPHITSを用いて,PHITSの利用初学者においても簡便に作成できる放射線の散乱を表した図を作成することで,端的かつ的確な放射線防護教育と不必要な被ばくへの注意喚起ができると考えられる。(著者)

Additional details

Additional titles

Original title (Japanese)
放射線防護教育を目的としたX線撮影室における散乱線の可視化

Identifiers

Publishing Information

Journal Title
Radioisotopes (Online)
Journal Volume
67
Journal Issue
1
Journal Page Range
p. 11-15
ISSN
1884-4111

Optional Information

Notes
6 refs., 4 figs.