Published June 21, 2016 | Version v1
Journal article

On the importance of body posture and skin modelling with respect to in situ electric field strengths in magnetic field exposure scenarios

  • 1. Seibersdorf Laboratories, EMC and Optics, A-2444 Seibersdorf (Austria)

Description

The reference levels and maximum permissible exposure values for magnetic fields that are currently used have been derived from basic restrictions under the assumption of upright standing body models in a standard posture, i.e. with arms laterally down and without contact with metallic objects. Moreover, if anatomical modelling of the body was used at all, the skin was represented as a single homogeneous tissue layer. In the present paper we addressed the possible impacts of posture and skin modelling in scenarios of exposure to a 50 Hz uniform magnetic field on the in situ electric field strength in peripheral tissues, which must be limited in order to avoid peripheral nerve stimulation. We considered different body postures including situations where body parts form large induction loops (e.g. clasped hands) with skin-to-skin and skin-to-metal contact spots and compared the results obtained with a homogeneous single-layer skin model to results obtained with a more realistic two-layer skin representation consisting of a low-conductivity stratum corneum layer on top of a combined layer for the cellular epidermis and dermis. Our results clearly indicated that postures with loops formed of body parts may lead to substantially higher maximum values of induced in situ electric field strengths than in the case of standard postures due to a highly concentrated current density and in situ electric field strength in the skin-to-skin and skin-to-metal contact regions. With a homogeneous single-layer skin, as is used for even the most recent anatomical body models in exposure assessment, the in situ electric field strength may exceed the basic restrictions in such situations, even when the reference levels and maximum permissible exposure values are not exceeded. However, when using the more realistic two-layer skin model the obtained in situ electric field strengths were substantially lower and no violations of the basic restrictions occurred, which can be explained by the current-limiting effect of the low-conductivity stratum corneum layer. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/0031-9155/61/12/4412

Additional details

Identifiers

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
61
Journal Issue
12
Journal Page Range
p. 4412-4437
ISSN
0031-9155
CODEN
PHMBA7

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
49090892
Subject category
S71: CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS;
Descriptors DEI
ELECTRIC FIELDS; EPIDERMIS; INDUCTION; MAGNETIC FIELDS; MAXIMUM PERMISSIBLE EXPOSURE; NERVES; SIMULATION; STIMULATION
Descriptors DEC
ANIMAL TISSUES; BODY; EPITHELIUM; NERVOUS SYSTEM; ORGANS; SAFETY STANDARDS; SKIN; STANDARDS