Published November 2010 | Version v1
Book

Whip restraint load analysis and calculation of main feedwater pipeing in nuclear power station

Creators

  • 1. guangdong Electric Power Design Inst., Guangzhou (China)

Description

This paper introduced the pipe wipe restraint device in CPR1000 nuclear power station, and gave a brief introduction of whip restraint design load analysis methods. Static analysis approach was adopted to study the main feedwater piping whip restraint load, and the study process could be applied in similar projects. (authors)

Part of:
Progress report on nuclear science and technology in China (Vol.1). Proceedings of academic annual meeting of China Nuclear Society in 2009, No.3--nuclear power sub-volume (Pt.2)

Additional details

Publishing Information

Publisher
Atomic Energy Press
Imprint Place
Beijing (China)
ISBN
978-7-5022-5040-9
Imprint Title
Progress report on nuclear science and technology in China (Vol.1). Proceedings of academic annual meeting of China Nuclear Society in 2009, No.3--nuclear power sub-volume (Pt.2)
Imprint Pagination
621 p.
Journal Page Range
p. 858-862

Conference

Title
academic annual meeting of China Nuclear Society
Acronym
'09
Dates
18-20 Nov 2009
Place
Beijing (China)

Optional Information

Notes
2 figs., 1 tab., 3 refs.