Published June 2013 | Version v1
Journal article

The improved output performance of a broad-area vertical-cavity surface-emitting laser with an optimized electrode diameter

  • 1. State Key Laboratory of Luminescence and Applications, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033 (China)

Description

The output performance of a 980-nm broad-area vertical-cavity surface-emitting laser (VCSEL) is improved by optimizing the p-electrode diameter in this study. Based on a three-dimensional finite-element method, the current density distribution within the active region of the VCSEL is optimized through the appropriate adjustment of the p-electrode diameter, and uniform current-density distribution is achieved. Then, the effects of this optimization are studied experimentally. The L—I—V characteristics under different temperatures of the VCSELs with different p-electrode diameters are investigated, and better temperature stability is demonstrated in the VCSEL with an optimized p-electrode diameter. The far-field measurements show that with an injected current of 2 A, the far-field divergence angle of the VCSEL with an optimized p-electrode diameter is 9°, which is much lower than the far-field angle of the VCSEL without this optimization. Also the VCSEL with an optimized p-electrode diameter shows a better near-field distribution

Availability note (English)

Available from http://dx.doi.org/10.1088/1674-1056/22/6/064209

Additional details

Publishing Information

Journal Title
Chinese Physics. B
Journal Volume
22
Journal Issue
6
Journal Page Range
[6 p.]
ISSN
1674-1056