Published 1988 | Version v1
Book

Water chemistry management during hot functional test

  • 1. Mitsubishi Atomic Power Industries, Inc., Omiya, Saitama (Japan). Engineering and Development Div.

Description

To reduce radiation exposure in light water reactor, it is important decrease radioactive corrosion product which is a radiation source. One of the countermeasures is to improve water quality during plant trial operation to form a stable oxide film and to minimize metal release to the coolant at the beginning of commercial operation. This study reviews the optimum water quality conditions to form a chromium rich oxide film during hot functional test (HFT) that is thought to be stable under the PWR condition and reduce the release of Ni that is the source of Co-58, the main radiation source of exposure. (author)

Additional details

Publishing Information

Publisher
Japan Atomic Industrial Forum.
Imprint Place
Tokyo (Japan)
Imprint Title
Proceedings of 1988 JAIF international conference on water chemistry in nuclear power plants
Imprint Pagination
843 p.
Journal Page Range
v. 2 p. 670-673.

Conference

Title
1988 JAIF international conference on water chemistry in nuclear power plants.
Dates
19-22 Apr 1988.
Place
Tokyo (Japan).

Optional Information

Notes
Imprint:Composed of two volumes.