Published 1987 | Version v1
Report Open

Combined scintillation and track technique to search for ββ-decay

Description

A variant of the scintillation spectrometer with wire chambers for ββ-decay search is considered. The time-of-flight technique for background suppression is suggested. The (-3 m2) source placed in the centre of the facility comprises three planes. Four wire chambers measure particle tracks in the centre of the source. The whole volume is filled with helium. Scintillation counters are produced of long plates. Four plates form a counter with two fast photomultipliers on both edges. Electron time-of-flight between the scintillators makes up 2-5 ns. If the mass of the (150Nd) source is equal to 75 g, then the half-decay period may be measured T1/2=1022 years

Availability note (English)

MF available from INIS under the Report Number.

Files

20019528.pdf

Files (121.8 kB)

Name Size Download all
md5:0cb275940c8f45627f3c4dca980057a3
121.8 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
4 p.
Report number
JINR-E--13-87-309

Optional Information

Notes
6 refs.; 1 fig.; submitted to the journal NIM.