Published April 1977 | Version v1
Report Open

Experiment data report for Semiscale Mod-1 Test S-05-5 (alternate ECC injection test)

Description

Recorded test data are presented for Test S-05-5 of the Semiscale Mod-1 alternate ECC injection test series. These tests are among several Semiscale Mod-1 experiments conducted to investigate the thermal and hydraulic phenomena accompanying a hypothesized loss-of-coolant accident in a pressurized water reactor (PWR) system. Test S-05-5 was conducted from initial conditions of 2263 psia and 5370F to investigate the response of the Semiscale Mod-1 system to a depressurization and reflood transient following a simulated double-ended offset shear of the cold leg broken loop piping. During the test, cooling water was injected into the cold leg of the intact and broken loops to simulate emergency core coolant injection in a PWR. The upper plenum was vented through a reflood bypass line interconnecting the hot and cold legs of the broken loop

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A11/MF A01.

Files

8328182.pdf

Files (8.2 MB)

Name Size Download all
md5:1625a16b4e4ac60328e018d6a2469f97
8.2 MB Preview Download

Additional details

Additional titles

Augmented title (English)
PWR

Publishing Information

Imprint Pagination
237 p.
Report number
TREE-NUREG--1054