Published May 2010
| Version v1
Journal article
First charge exchange recombination spectroscopy diagnostic in HL-2A tokamak
Creators
- 1. Southwestern Inst. of Physics, Chengdu (China)
Description
Spatially resolved measurements of ion temperature are crucial for understanding plasma dynamics. A charge exchange recombination spectroscopy diagnostic system based on a heating neutral beam is installed on the HL-2A tokamak. An optical collection system is designed in accordance with the actual geometry of HL-2A and the CVI 529.2 nm (n=8→7) charge-exchange recombination line. Preliminary measurements show that the CX signals have enough signal-to-noise ratio (SNR). The ion temperature and its profiles are obtained through this system for the first time. (authors)
Additional details
Publishing Information
- Journal Title
- Chinese Physics Letters
- Journal Volume
- 27
- Journal Issue
- 5
- Journal Page Range
- [3 p.]
- ISSN
- 0256-307X
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 42023028
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- BEAM INJECTION HEATING; CHARGE EXCHANGE; HL-2A TOKAMAK; ION TEMPERATURE; OPTICAL SYSTEMS; PLASMA DIAGNOSTICS; RECOMBINATION; SIGNAL-TO-NOISE RATIO; SPATIAL RESOLUTION; SPECTROSCOPY; TEMPERATURE DISTRIBUTION
- Descriptors DEC
- CLOSED PLASMA DEVICES; DIMENSIONLESS NUMBERS; HEATING; PLASMA HEATING; RESOLUTION; THERMONUCLEAR DEVICES; TOKAMAK DEVICES
Optional Information
- Notes
- 7 figs., 18 refs.