Published January 1989 | Version v1
Journal article

Control of electronegative impurity content in liquid krypton by means of an emission detector

  • 1. Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Moscow (USSR). Inst. Teoreticheskoj i Ehksperimental'noj Fiziki

Description

Technique to control the electronegative impurity content in the condensed dielectrics, bearing radiactive impurities, for example, in liquid krypton, which natural mixture of isotopes contains 85Kr β-active isotope, is suggested. Length of electron drift before their capture by electronegative impurities in 8 dm3 volume liquid krypton is measured by means of this technique. It constituted 3.3±0.5 cm after krypton purification in gaseous state using kieselguhr-base nickel getter

Additional details

Additional titles

Original title (Russian)
Контрол' содержания электроотрицательных примесей в жидком криптоне с помощью эмиссионного детектора

Publishing Information

Journal Title
Pribory i Tekhnika Ehksperimenta
Journal Issue
no.1
Series
Prib. Tekh. Ehksp.
ISSN
0032-8162
CODEN
PRTEA