Published October 1994 | Version v1
Journal article

Standardization of the method for measurement of plasma estrone by radioimmunoassay

  • 1. Sao Paulo Univ., Ribeirao Preto, SP (Brazil). Faculdade de Medicina

Description

The present paper has as objective standardize a radioimmunoassay method for measurement of plasma estrone. Ethyl ether was used for plasma extraction. The sensitivity (Minimal detectable dose) was 3,7 pg/tube; the reproducibility (inter assay error) was 8,6%; the precision (intra assay error) was 4,1%. As a biological control the plasma estrone was ml) and in 24 patients with polycystic ovarian syndrome (median = 77,9 pg/ml). (author). 6 refs, 2 figs, 2 tabs

Additional details

Additional titles

Original title (Portuguese)
Padronizacao do metodo de dosagem de estrona plasmatica por radioimunoensaio

Publishing Information

Journal Title
Revista Brasileira de Patologia Clinica
Journal Volume
30
Journal Issue
4
Journal Page Range
p. 178-181.
ISSN
0034-7302
CODEN
RBPTBN