Published 2010 | Version v1
Miscellaneous

Circulation system of fluorinert in J-PARC ESS

  • 1. High Energy Accelerator Research Organization, Tsukuba, Ibaraki (Japan)
  • 2. Nippon Advanced Technology Co., Ltd., Tokai, Ibaraki (Japan)
  • 3. Univ. of Hukui, Hukui (Japan)

Description

The electro-static septum (ESS) comprise the cathode plate and thin ribbons which are stretched to the yoke in J-PARC. Two electric septa are used upstream of septum magnets. Fluorinert FC40 are chosen as an insulation liquid for the feedthrough and cable connection device. Since the viscosity is small, it is easy to handle, additionally, in case that the feedthrough is broken by the spark, it would reduce the risk of contamination of the vacuum. The demerit of fluorinert is that the degradation product such as hydrogen fluoride (HF) is created under the high radiation environment. The circulation system was introduced in order to eliminate HF. We report the circulation system of fluorinert and the result of the filtration. (author)

Part of:
Proceedings of the 7th annual meeting of Particle Accelerator Society of Japan

Additional details

Additional titles

Original title (Japanese)
Dai 7 kai nippon kasokuki gakkai nenkai

Publishing Information

Imprint Title
Proceedings of the 7th annual meeting of Particle Accelerator Society of Japan
Imprint Pagination
[1232 p.]
Journal Page Range
[3 p.]

Conference

Title
7. annual meeting of Particle Accelerator Society of Japan
Dates
4-6 Aug 2010
Place
Himeji, Hyogo (Japan)

Optional Information

Notes
4 refs., 6 figs., 3 tabs. Imprint:Dai 7 kai nippon kasokuki gakkai nenkai