Published September 2018 | Version v1
Journal article

Near infrared emission spectroscopy for rapid compositional analysis of Portland cements

  • 1. Chemistry Institute, University of Campinas – UNICAMP, 13083-970, Cidade Universitária, Campinas, SP (Brazil)

Description

Highlights: • Near infrared emission spectroscopy was used for cement samples analysis. • The six main oxides have been estimated in Portland cement samples. • An emission spectrometer was specially assembled for the method development. • Emission spectra were correlated with reference analysis using chemometric models. • No sample preparation is required and analysis takes only 6 min per sample. - Abstract: Near infrared emission spectroscopy (NIRES) has been investigated to yield a new analytical method for determination of CaO, SiO2, Al2O3, Fe2O3, MgO, and SO3 in Portland cement samples. The analyses were accomplished by correlation of the second derivative NIRES spectra with reference elemental analyses made by X-ray Fluorescence (XRF), using Partial Least Square (PLS) regression models. Four different types of cements (type II, III, IV and V) were included in the models. The results show RMSEP from 0.18 to 1.67% (m/m) (which represents 8.6 to 2.8% of the mean value parameters, respectively) and precision (repeatability) from 0.12 to 1.49% (m/m). The worse performance of prediction [RMSEP = 0.18% (m/m), r2 = 0.63] was found for Fe2O3 determination due its low variability in the samples employed in the calibration and validation set, usual low content in cements, and high correlation with the weak emitting C4AF phase. However, the paired t-test at 95% confidence level demonstrated that the analytical results obtained by NIRES multivariate models are equivalent to measurements performed by XRF for all oxides analyzed. The cost, speed and safety aspects are improved in comparison with the XRF method. The method based on NIRES requires no sample preparation and speed up the cement analysis (6 min) about 5 times when compared with the method based on XRF presently employed by cement industries.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.aca.2018.03.035

Additional details

Identifiers

DOI
10.1016/j.aca.2018.03.035;
PII
S0003267018304148;

Publishing Information

Journal Title
Analytica Chimica Acta
Journal Volume
1024
Journal Page Range
p. 136-144
ISSN
0003-2670
CODEN
ACACAM

Optional Information

Copyright
Copyright (c) 2017 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.