Published November 8, 1979 | Version v1
Report Restricted

Design and testing of low capacitance, 80-kV source cables for MFTF sustaining neutral beam power supplies

Description

In this paper we summarize characteristics of several cable configurations and consider one design in detail, which consists of twelve, 250 MCM arc cables, ten 4/0 filament cables, and accel, gradient grid, control, and instrumentation cables within a circular split Al pipe. The pipe is air insulated from an outer 24-in. x 24-in. steel duct by utility pin insulators. Varying run lengths require adjustment of the arc inductance by variation of cross sectional cable position. Equilibrium heat transfer analysis indicates the pulse-off time for source conditioning must be somewhat greater than 60 s to keep conductor temperatures below 900C. The results of a high voltage test of a model cable are presented

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
6 p.
Report number
UCRL--82954

Conference

Title
8. symposium on engineering problems of fusion research.
Dates
13 - 16 Nov 1979.
Place
San Francisco, CA, USA.

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
11519378
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ATOMIC BEAM SOURCES; ELECTRIC CABLES; MFTF DEVICES; PERFORMANCE TESTING; POWER SUPPLIES; SPECIFICATIONS
Descriptors DEC
CONDUCTOR DEVICES; ELECTRICAL EQUIPMENT; ELECTRONIC EQUIPMENT; MAGNETIC MIRRORS; OPEN PLASMA DEVICES; TESTING; THERMONUCLEAR DEVICES

Optional Information

Secondary number(s)
CONF-791102--28.