Published November 1989 | Version v1
Journal article

Flow recirculation data for closed-ended branch piping (deep cavity flow)

  • 1. Westinghouse Electric Corporation, Madison, PA (USA)

Description

Many auxiliary lines of different sizes are tied into the primary heat transport system piping of nuclear reactors and other similar types of systems. Often these lines are valve closed so that the contained fluid is either stagnant or flowing at low velocity due to free convection or small amounts of valve leakage. The characterization of the axial temperature distributions in these lines is important because of potential structural consequences to the piping. For example, in addition to being required for determining basic thermal expansion allowances in piping networks, axial temperature distributions are needed relative to other considerations, such as thermal fatigue, which could occur because the leakage flow has a different temperature from that of the trunk line that it flows into at the juncture of the two pipes. As would be anticipated, conditions that result in larger fluid temperature differences at a particular network juncture generally result in the more severe structural impact (e.g., thermal stratification/striping assessments become necessary). Prediction of the flow recirculation back into the branch piping is critical for calculation of the junction temperatures and is the subject of this study

Additional details

Publishing Information

Journal Title
Transactions of the American Nuclear Society
Journal Volume
60
Series
Trans. Am. Nucl. Soc.
Journal Page Range
676-677
ISSN
0003-018X
CODEN
TANSA

Conference

Title
Winter meeting of the American Nuclear Society (ANS) and nuclear power and technology exhibit.
Dates
26-30 Nov 1989.
Place
San Francisco, CA (USA).

Optional Information

Secondary number(s)