Published 1994 | Version v1
Miscellaneous

Two-phase counter-current flow limitations in complex piping systems

  • 1. McMaster Univ., Hamilton, ON (Canada)

Description

Experiments have been performed to investigate two-phase air-water countercurrent flow limitations in two complex geometry test sections. One of the test sections was chosen to represent the complexity of CANDU feeders, at a 1:4 scale. In the second configuration, the effect of declining the horizontal parts of the test section was investigated. For the tested geometry, the results showed that the onset of flooding occurs at lower gas velocity as compared to those required to initiate flooding in vertical tubes or single 90 deg vertical bends. However, the critical gas velocity at the zero liquid penetration limit was found to be comparable to that of a 90 deg vertical bend. (author) 18 refs., 10 figs

Part of:
Proceedings of the Canadian Nuclear Society 15. annual conference

Additional details

Publishing Information

Imprint Title
Proceedings of the Canadian Nuclear Society 15. annual conference
Imprint Pagination
[1000 p.].
Journal Page Range
(v.1) [23 p.].
ISSN
0227-1907
Report number
INIS-mf--14987(v.1,2)

Conference

Title
15. annual conference of the Canadian Nuclear Society; 34. annual conference of the Canadian Nuclear Association.
Dates
5-8 Jun 1994.
Place
Montreal, PQ (Canada).