Published February 1982 | Version v1
Report Open

Reverse osmosis application studies

Description

To assess the feasibility of applying reverse osmosis (RO) and ultrafiltration (UF) for effective treatment of process and waste streams from operations at Ontario Hydro's thermal and nuclear stations, an extensive literature survey has been carried out. It is concluded that RO is not at present economic for pretreatment of Great Lakes water prior to ion exchange demineralization for boiler makeup. Using both conventional and novel commercial membrane modules, RO pilot studies are recommended for treatment of boiler cleaning wastes, fly ash leachates, and flue gas desulphurization scrubber discharges for removal of heavy metals. Volume reduction and decontamination of nuclear station low-level active liquid waste streams by RO/UF also appear promising. Research programmes are proposed

Availability note (English)

MF available from INIS under the Report Number.

Files

15007079.pdf

Files (845.9 kB)

Name Size Download all
md5:fcba7417df2ef6ba77feb5af40ff8867
845.9 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
44 p.
Report number
OH--81-497-K

Optional Information

Notes
41 refs.