Published May 15, 1981
| Version v1
Journal article
Improved performance of the Munich MP tandem: A status report
Creators
- 1. Beschleunigerlaboratorium der Univ. und Technischen Univ. Muenchen, Garching (Germany, F.R.)
- 2. Muenchen Univ. (Germany, F.R.). Sektion Physik
Description
Operating experience and some of the modifications introduced during the last two years are reported. During the past year the terminal voltage obtained in test runs, the voltage used during experiments and the operating efficiency of the accelerator have improved considerably. The spectrum of ions available in routine operations has been extended to include 14C, 30Si, 36S, 48Ca and 60Ni beams. (orig.)
Additional details
Publishing Information
- Journal Title
- Nucl. Instrum. Methods
- Journal Volume
- 184
- Journal Issue
- 1
- Series
- Nucl. Instrum. Methods.
- Journal Page Range
- 87-91
- ISSN
- 0029-554X
Conference
- Title
- 5. Tandem conference.
- Dates
- 9 - 12 Jun 1980.
- Place
- Catania, Italy.
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 12632775
- Subject category
- S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AVAILABILITY; EFFICIENCY; FEDERAL REPUBLIC OF GERMANY; ION BEAMS; OPERATION; PERFORMANCE; TANDEM ELECTROSTATIC ACCELERAT
- Descriptors DEC
- ACCELERATORS; BEAMS; ELECTROSTATIC ACCELERATORS; EUROPE